Project Items
Line | Item Number | Description | Units | Quantity |
---|---|---|---|---|
Base Bid | ||||
DRAINAGE-01 | ||||
602E20000 | CONCRETE MASONRY | CY | 1 | |
605E13300 | 6" UNCLASSIFIED PIPE UNDERDRAINS | FT | 100 | |
605E14000 | 6" BASE PIPE UNDERDRAINS | FT | 2,420 | |
611E00510 | 6" CONDUIT, TYPE F FOR UNDERDRAIN OUTLETS | FT | 290 | |
611E04400 | 12" CONDUIT, TYPE B | FT | 326 | |
611E04600 | 12" CONDUIT, TYPE C | FT | 93 | |
611E07400 | 18" CONDUIT, TYPE B | FT | 34 | |
611E07600 | 18" CONDUIT, TYPE C | FT | 198 | |
611E10400 | 24" CONDUIT, TYPE B | FT | 130 | |
611E52302 | 19" X 30" CONDUIT, TYPE B, 706.04 | FT | 36 | |
611E52504 | 24" X 38" CONDUIT, TYPE C, 706.04 | FT | 179 | |
611E98150 | CATCH BASIN, NO. 3 | EACH | 7 | |
611E98151 | CATCH BASIN, NO. 3, AS PER PLAN | EACH | 6 | |
611E98540 | CATCH BASIN, NO. 2-4 | EACH | 2 | |
611E98690 | CATCH BASIN, MISC.: Conduit Connection to Existing Catch Basin |
EACH | 5 | |
611E99574 | MANHOLE, NO. 3 | EACH | 3 | |
611E99586 | MANHOLE, NO. 3 WITH 108" BASE I.D. AND 12" WEIR | EACH | 1 | |
611E99654 | MANHOLE ADJUSTED TO GRADE | EACH | 8 | |
611E99710 | PRECAST REINFORCED CONCRETE OUTLET | EACH | 1 | |
613E41200 | LOW STRENGTH MORTAR BACKFILL | CY | 317 | |
895E10040 | MANUFACTURED WATER QUALITY STRUCTURE, TYPE 4 | EACH | 1 | |
ENVIROMENTAL / REMEDIATION-01 | ||||
690E65010 | SPECIAL - WORK INVOLVING SOLID WASTE | TON | 50 | |
690E65024 | SPECIAL - WORK INVOLVING REGULATED WATER | GAL | 100 | |
690E98000 | SPECIAL - Laboratory Analysis for Petroleum Contaminated Soils |
EACH | 2 | |
690E98400 | SPECIAL - Monitoring for Petroleum Contaminated Soils |
LS | 1 | |
690E98800 | SPECIAL - Disposal of Petroleum Contaminated Soils |
TON | 75 | |
EROSION CONTROL-01 | ||||
601E21050 | TIED CONCRETE BLOCK MAT, TYPE 1 | SY | 2 | |
601E32204 | ROCK CHANNEL PROTECTION, TYPE C WITH GEOTEXTILE FABRIC | CY | 4 | |
659E00100 | SOIL ANALYSIS TEST | EACH | 1 | |
659E00300 | TOPSOIL | CY | 620 | |
659E00501 | SEEDING AND MULCHING, CLASS 1, AS PER PLAN | SY | 5,123 | |
659E14001 | REPAIR SEEDING AND MULCHING, AS PER PLAN | SY | 211 | |
659E15001 | INTER-SEEDING, AS PER PLAN | SY | 211 | |
659E20000 | COMMERCIAL FERTILIZER | TON | 0.59 | |
659E31000 | LIME | ACRE | 0.87 | |
659E35000 | WATER | MGAL | 24 | |
691E00500 | SPECIAL - HERBICIDE FOR WEED CONTROL | SY | 5,123 | |
832E15000 | STORM WATER POLLUTION PREVENTION PLAN This item includes all costs associated with the development, implementation, inspection and the required documentation of a Storm Water Pollution Prevention Plan for the Project described in this Contract. all of the specifications and requirements of ODOT supplemental specification 832 shall apply. |
LS | 1 | |
832E15002 | STORM WATER POLLUTION PREVENTION INSPECTIONS | LS | 1 | |
832E15010 | STORM WATER POLLUTION PREVENTION INSPECTION SOFTWARE | LS | 1 | |
832E30000 | EROSION CONTROL This item is for the installation of Storm Water BMPS as defined in appendix "F" of ODOT supplemental specifications 832. The Contractor shall enter $1.00 in the unit price column and $45,000.00 in the total column. If the Contractor neglects to enter the correct figure(s) the Contractors bid will be corrected and the process for "Mistake In Bid" shall follow. No work will be recognized or paid under this item unless agreed upon and approved by an authorized representative of the Butler County Engineer's Office. |
EACH | 45,000 | |
900E20000A | SPECIAL: TURF REINFORCEMENT | SY | 146 | |
INCIDENTALS | ||||
614E11000 | MAINTAINING TRAFFIC | LS | 1 | |
619E16010 | FIELD OFFICE, TYPE B | MNTH | 9 | |
623E10000 | CONSTRUCTION LAYOUT STAKES AND SURVEYING | LS | 1 | |
624E10000 | MOBILIZATION | LS | 1 | |
802E00001 | PREMIUM ON INDUSTRIAL INSURANCE | LS | 1 | |
802E00002 | PREMIUM ON BID BOND | LS | 1 | |
802E00003 | CONTINGENCIES The Contractor shall enter $1.00 in the unit price column and $85,000.00 in the total column. If the Contractor neglects to enter the correct figure(s), the Contractor's bid will be corrected and the process for "Mistake in Bid" shall follow. This item will be used in the event that there are change orders in the Contract. No work will be paid or recognized under this item unless agreed upon in writing by an authorized representative of the Butler County Engineer's Office. |
EA | 85,000 | |
LIGHTING-01 | ||||
625E00450 | CONNECTION, FUSED PULL APART | EACH | 11 | |
625E00480 | CONNECTION, UNFUSED PERMANENT | EACH | 25 | |
625E10491 | LIGHT POLE, CONVENTIONAL, AS PER PLAN | EACH | 11 | |
625E14500 | LIGHT POLE FOUNDATION | EACH | 11 | |
625E23200 | NO. 4 AWG 2400 VOLT DISTRIBUTION CABLE | FT | 3,306 | |
625E23400 | NO. 10 AWG POLE AND BRACKET CABLE | FT | 1,080 | |
625E25500 | CONDUIT, 3", 725.04 | FT | 696 | |
625E26253 | LUMINAIRE, CONVENTIONAL, SOLID STATE (LED), AS PER PLAN | EACH | 11 | |
625E30700 | PULL BOX, 725.08, 18" | EACH | 13 | |
625E32000 | GROUND ROD | EACH | 12 | |
625E34001 | POWER SERVICE, AS PER PLAN | EACH | 1 | |
625E36000 | PLASTIC CAUTION TAPE | FT | 696 | |
625E40000 | SPECIAL - MAINTAIN EXISTING LIGHTING | LS | 1 | |
625E75400 | LIGHT POLE REMOVED | EACH | 1 | |
MAINTENANCE OF TRAFFIC-01 | ||||
614E11110 | LAW ENFORCEMENT OFFICER WITH PATROL CAR FOR ASSISTANCE | HOUR | 96 | |
614E11300 | SPECIAL - WORK ZONE TRAFFIC SIGNAL | EACH | 1 | |
614E12336 | WORK ZONE IMPACT ATTENUATOR (UNIDIRECTIONAL) | EACH | 2 | |
614E12600 | REPLACEMENT DRUM | EACH | 50 | |
614E13312 | BARRIER REFLECTOR, TYPE 2 Bi-Directional |
EACH | 68 | |
614E13360 | OBJECT MARKER, TWO WAY | EACH | 68 | |
614E18000 | MAINTAINING TRAFFIC, MISC.: Tapered End Section |
EACH | 5 | |
614E18600 | PORTABLE CHANGEABLE MESSAGE SIGN | SNMT | 5 | |
614E18601 | PORTABLE CHANGEABLE MESSAGE SIGN, AS PER PLAN | SNMT | 20 | |
614E21000 | WORK ZONE CENTER LINE, CLASS I | MILE | 0.4 | |
614E22000 | WORK ZONE EDGE LINE, CLASS I, 4" | MILE | 0.89 | |
614E24000 | WORK ZONE DOTTED LINE, CLASS I | FT | 776 | |
614E25000 | WORK ZONE TRANSVERSE/DIAGONAL LINE, CLASS I | FT | 45 | |
614E26000 | WORK ZONE STOP LINE, CLASS I | FT | 51 | |
614E30000 | WORK ZONE ARROW, CLASS I | EACH | 2 | |
615E10000 | ROADS FOR MAINTAINING TRAFFIC | LS | 1 | |
615E20000 | PAVEMENT FOR MAINTAINING TRAFFIC, CLASS A | SY | 1,810 | |
616E10000 | WATER | MGAL | 5 | |
622E41100 | PORTABLE BARRIER, UNANCHORED | FT | 1,610 | |
PAVEMENT-01 | ||||
254E01000 | PAVEMENT PLANING, ASPHALT CONCRETE | SY | 3,029 | |
301E46000 | ASPHALT CONCRETE BASE, PG64-22 | CY | 838 | |
304E20000 | AGGREGATE BASE | CY | 913 | |
407E20000 | NON-TRACKING TACK COAT | GAL | 633 | |
441E50000 | ASPHALT CONCRETE SURFACE COURSE, TYPE 1, (448), PG64-22 | CY | 320 | |
441E50300 | ASPHALT CONCRETE INTERMEDIATE COURSE, TYPE 2, (448) | CY | 205 | |
451E14011 | 9" REINFORCED CONCRETE PAVEMENT, CLASS QC 1P, AS PER PLAN | SY | 456 | |
451E20000 | REINFORCED CONCRETE PAVEMENT, MISC.: (Stamped) As Per Plan |
SY | 3 | |
452E10010 | 6" NON-REINFORCED CONCRETE PAVEMENT, CLASS QC 1P | SY | 40 | |
609E12000 | COMBINATION CURB AND GUTTER, TYPE 2 | FT | 2,272 | |
609E18000 | COMBINATION CURB AND GUTTER, TYPE 3 | FT | 66 | |
609E26000 | CURB, TYPE 6 | FT | 324 | |
609E31001 | COMBINATION CURB AND GUTTER, TYPE 9, AS PER PLAN | FT | 393 | |
609E72000 | CONCRETE MEDIAN | SY | 298 | |
PAVEMENT-02 | ||||
254E01001 | PAVEMENT PLANING, ASPHALT CONCRETE, AS PER PLAN | SY | 66 | |
ROADWAY-01 | ||||
201E11000 | CLEARING AND GRUBBING | LS | 1 | |
202E11201 | PORTIONS OF STRUCTURE REMOVED, AS PER PLAN Building Foundation and Footing |
LS | 1 | |
202E23000 | PAVEMENT REMOVED | SY | 113 | |
202E23010 | PAVEMENT REMOVED, ASPHALT | SY | 6,919 | |
202E30000 | WALK REMOVED | SF | 281 | |
202E30800 | TRAFFIC ISLAND REMOVED | SY | 73 | |
202E32000 | CURB REMOVED | FT | 2,201 | |
202E35100 | PIPE REMOVED, 24" AND UNDER | FT | 1,216 | |
202E35200 | PIPE REMOVED, OVER 24" | FT | 116 | |
202E58100 | CATCH BASIN REMOVED | EACH | 16 | |
202E67000 | REGULATED UNDERGROUND STORAGE TANK REMOVED | EACH | 7 | |
203E10000 | EXCAVATION | CY | 574 | |
203E20000 | EMBANKMENT | CY | 3,283 | |
204E10000 | SUBGRADE COMPACTION | SY | 5,683 | |
204E13000 | EXCAVATION OF SUBGRADE | CY | 1,931 | |
204E30020 | GRANULAR MATERIAL, TYPE C | CY | 1,931 | |
204E45000 | PROOF ROLLING | HOUR | 6 | |
204E50000 | GEOTEXTILE FABRIC | SY | 5,793 | |
607E30000 | FENCE, SNOW | FT | 96 | |
638E10480 | FIRE HYDRANT REMOVED | EACH | 1 | |
690E50350 | SPECIAL - MAILBOX REMOVED AND RESET | EACH | 12 | |
878E25000 | INSPECTION AND COMPACTION TESTING OF UNBOUND MATERIALS | LS | 1 | |
ROADWAY-02 | ||||
204E10000 | SUBGRADE COMPACTION | SY | 616 | |
608E12000 | 5" CONCRETE WALK | SF | 4,121 | |
608E52000 | CURB RAMP | SF | 1,965 | |
608E53020 | DETECTABLE WARNING | SF | 162 | |
TRAFFIC CONTROL-01 | ||||
621E00100 | RPM | EACH | 89 | |
630E03100 | GROUND MOUNTED SUPPORT, NO. 3 POST | FT | 250 | |
630E03101 | GROUND MOUNTED SUPPORT, NO. 3 POST, AS PER PLAN | FT | 306 | |
630E08600 | SIGN POST REFLECTOR | EACH | 10 | |
630E80100 | SIGN, FLAT SHEET | SF | 299.5 | |
630E84900 | REMOVAL OF GROUND MOUNTED SIGN AND DISPOSAL | EACH | 4 | |
630E86002 | REMOVAL OF GROUND MOUNTED POST SUPPORT AND DISPOSAL | EACH | 4 | |
630E87520 | REMOVAL OF POLE MOUNTED SIGN AND REERECTION | EACH | 7 | |
644E00100 | EDGE LINE, 4" | MILE | 0.3 | |
644E00300 | CENTER LINE | MILE | 0.33 | |
644E00400 | CHANNELIZING LINE, 8" | FT | 213 | |
644E01300 | LANE ARROW | EACH | 2 | |
644E01514 | DOTTED LINE, 8" | FT | 49 | |
644E20800 | YIELD LINE | FT | 91 | |
TRAFFIC CONTROL-02 | ||||
630E03100 | GROUND MOUNTED SUPPORT, NO. 3 POST | FT | 75 | |
630E03101 | GROUND MOUNTED SUPPORT, NO. 3 POST, AS PER PLAN | FT | 75 | |
630E80100 | SIGN, FLAT SHEET | SF | 82.5 | |
644E00600 | CROSSWALK LINE | FT | 344 | |
TRAFFIC SIGNALS-01 | ||||
632E90300 | SIGNALIZATION, MISC.: Removal of Traffic Signal Installation, As Per Plan |
LS | 1 | |
WATER WORK-02 | ||||
638E10800 | VALVE BOX ADJUSTED TO GRADE | EACH | 11 | |
638E98000 | WATER WORK, MISC.: Water Services Abandon to Main |
EACH | 7 | |
Alternate 1 | ||||
ALTERNATE #1 | ||||
611E04400 | 12" CONDUIT, TYPE B | FT | 38 | |
611E07400 | 18" CONDUIT, TYPE B | FT | 101 | |
611E10400 | 24" CONDUIT, TYPE B | FT | 234 | |
611E13400 | 30" CONDUIT, TYPE B | FT | 45 | |
611E16400 | 36" CONDUIT, TYPE B | FT | 64 | |
611E16600 | 36" CONDUIT, TYPE C | FT | 227 | |
Alternate 2 | ||||
ALTERNATE #2 | ||||
611E04401 | 12" CONDUIT, TYPE B, AS PER PLAN 706.01 |
FT | 38 | |
611E07401 | 18" CONDUIT, TYPE B, AS PER PLAN 707.24 |
FT | 101 | |
611E10401 | 24" CONDUIT, TYPE B, AS PER PLAN 706.01 |
FT | 234 | |
611E13401 | 30" CONDUIT, TYPE B, AS PER PLAN 706.01 |
FT | 45 | |
611E16401 | 36" CONDUIT, TYPE B, AS PER PLAN 706.01 |
FT | 64 | |
611E16601 | 36" CONDUIT, TYPE C, AS PER PLAN 706.01 |
FT | 227 |