Project Items
Line | Item Number | Description (Hide All Extended Descriptions) | Units | Quantity |
---|---|---|---|---|
DRAINAGE | ||||
604E00401 | CATCH BASIN, NO. 3, AS PER PLAN | EACH | 3 | |
605E05100 | 4" SHALLOW PIPE UNDERDRAINS | FT | 3,950 | |
BC811E044001 | 12" CONDUIT, TYPE B | FT | 902 | |
BC811E11900 | 27" CONDUIT, TYPE B | FT | 17 | |
BC811E16400 | 36" CONDUIT, TYPE B | FT | 25 | |
BC811E315001 | MANHOLE NO. 3 | EA | 3 | |
BC811E981501 | CATCH BASIN NO. 3 | EA | 19 | |
BC811E984701 | CATCH BASIN NO. 2-2B | EA | 1 | |
BC811E98510 | CATCH BASIN, NO 2-3 | EA | 2 | |
BC811E98630 | CATCH BASIN ADJUST TO GRADE | EA | 4 | |
BC811E99654 | MANHOLE ADJUSTED TO GRADE | EA | 12 | |
EROSION CONTROL | ||||
659E10001 | SEEDING AND MULCHING, AS PER PLAN | SY | 2,850 | |
659E14000 | REPAIR SEEDING AND MULCHING | SY | 143 | |
659E20000 | COMMERCIAL FERTILIZER | TON | 0.39 | |
659E35000 | WATER | MGAL | 8 | |
832E15000 | STORM WATER POLLUTION PREVENTION PLAN (Show Less) This item includes all costs associated with the development, implementation, inspection and the required documentation of a Storm Water Pollution Prevention Plan for the Project described in this Contract. all of the specifications and requirements of ODOT supplemental specification 832 shall apply. |
LS | 1 | |
832E30000 | EROSION CONTROL (Show Less) This item is for the installation of Storm Water BMPS as defined in appendix "F" of ODOT supplemental specifications 832. The Contractor shall enter $1.00 in the unit price column and $23,000.00 in the total column. If the Contractor neglects to enter the correct figure(s) the Contractors bid will be corrected and the process for "Mistake In Bid" shall follow. No work will be recognized or paid under this item unless agreed upon and approved by an authorized representative of the Butler County Engineer's Office. |
EACH | 23,000 | |
LIGHTING | ||||
625E25410 | CONDUIT, 2", 725.052 | FT | 1,100 | |
625E29401 | TRENCH IN PAVED AREAS, AS PER PLAN | FT | 1,100 | |
625E35011 | REMOVE AND REERECT EXISTING LIGHT POLE, AS PER PLAN | EACH | 6 | |
625E98000 | LIGHTING, MISC.: (Show Less) Relocate spot light for flag pole from existing station 18+14 |
EACH | 1 | |
625E98000 | LIGHTING, MISC.: (Show Less) Median Decorative Lighting, As Per Plan |
EACH | 59,000 | |
MAINTENANCE OF TRAFFIC | ||||
410E12000 | TRAFFIC COMPACTED SURFACE, TYPE A OR B | CY | 75 | |
410E13000 | TRAFFIC COMPACTED SURFACE, TYPE C | CY | 75 | |
614E11000 | MAINTAINING TRAFFIC | LS | 1 | |
614E11110 | LAW ENFORCEMENT OFFICER WITH PATROL CAR FOR ASSISTANCE | HOUR | 80 | |
614E13000 | ASPHALT CONCRETE FOR MAINTAINING TRAFFIC | CY | 75 | |
614E18601 | PORTABLE CHANGEABLE MESSAGE SIGN, AS PER PLAN | SNMT | 6 | |
614E21100 | WORK ZONE CENTER LINE, CLASS I, 642 PAINT | MILE | 0.5 | |
614E22100 | WORK ZONE EDGE LINE, CLASS I, 642 PAINT | MILE | 0.4 | |
614E23200 | WORK ZONE CHANNELIZING LINE, CLASS I, 642 PAINT | FT | 500 | |
614E26200 | WORK ZONE STOP LINE, CLASS I, 642 PAINT | FT | 50 | |
614E40051 | BUSINESS ENTRANCE SIGN, AS PER PLAN | EACH | 10 | |
616E10000 | WATER | MGAL | 2 | |
MISC | ||||
611E99700 | SPECIAL - GAS VALVE BOX ADJUSTED TO GRADE | EACH | 5 | |
619E16010 | FIELD OFFICE, TYPE B | MNTH | 6 | |
623E10000 | CONSTRUCTION LAYOUT STAKES AND SURVEYING | LS | 1 | |
624E10000 | MOBILIZATION | LS | 1 | |
802E00001 | PREMIUM ON INDUSTRIAL INSURANCE | LS | 1 | |
802E00002 | PREMIUM ON BID BOND | LS | 1 | |
802E00003 | CONTINGENCIES (Show Less) The Contractor shall enter $1.00 in the unit price column and $150,000.00 in the total column. If the Contractor neglects to enter the correct figure(s), the Contractor's bid will be corrected and the process for "Mistake in Bid" shall follow. This item will be used in the event that there are change orders in the Contract. No work will be paid or recognized under this item unless agreed upon in writing by an authorized representative of the Butler County Engineer's Office. |
EA | 150,000 | |
SPECE0100 | TRAFFIC BOX ADJUSTED TO GRADE | EA | 3 | |
SPECIAL02 | ELECTRIC METER REMOVED AND RESET | EA | 1 | |
SPECIAL14 | CROSSINGS AND CONNECTIONS TO EXISTING PIPES AND UTILITIES | EA | 15 | |
PAVEMENT | ||||
204E10000 | SUBGRADE COMPACTION | SY | 9,014 | |
204E45000 | PROOF ROLLING | HOUR | 6 | |
252E01500 | FULL DEPTH PAVEMENT SAWING | FT | 5,378 | |
254E01000 | PAVEMENT PLANING, ASPHALT CONCRETE | SY | 24,225 | |
301E46000 | ASPHALT CONCRETE BASE, PG64-22 | CY | 1,980 | |
304E20000 | AGGREGATE BASE | CY | 1,716 | |
407E20000 | NON-TRACKING TACK COAT | GAL | 2,945 | |
441E50000 | ASPHALT CONCRETE SURFACE COURSE, TYPE 1, (448), PG64-22 | CY | 1,333 | |
441E50300 | ASPHALT CONCRETE INTERMEDIATE COURSE, TYPE 2, (448) | CY | 333 | |
607ESPECIAL | CURB REMOVAL AND REPLACEMENT | FT | 607 | |
609E12000 | COMBINATION CURB AND GUTTER, TYPE 2 | FT | 3,704 | |
609E26000 | CURB, TYPE 6 | FT | 675 | |
609E28000 | CURB, TYPE 7 | FT | 155 | |
609E50000 | CONCRETE MEDIAN SAMPLE, AS PER PLAN | EA | 1 | |
609E72001 | CONCRETE MEDIAN, AS PER PLAN | SY | 1,580 | |
ROADWAY | ||||
201E11000 | CLEARING AND GRUBBING | LS | 1 | |
202E30000 | WALK REMOVED | SF | 4,096 | |
202E30200 | STEPS REMOVED | FT | 20 | |
202E32000 | CURB REMOVED | FT | 571 | |
202E32500 | CURB AND GUTTER REMOVED | FT | 2,646 | |
202E35100 | PIPE REMOVED, 24" AND UNDER | FT | 362 | |
202E35200 | PIPE REMOVED, OVER 24 | FT | 126 | |
202E53100 | MAILBOX REMOVED | EACH | 1 | |
202E58000 | MANHOLE REMOVED | EACH | 3 | |
202E58100 | CATCH BASIN REMOVED | EACH | 18 | |
202E70000 | SPECIAL - FILL AND PLUG EXISTING CONDUIT | FT | 195 | |
202E75000 | FENCE REMOVED | FT | 473 | |
202E981000A | REMOVAL MISC: (Show Less) Curb Ramp Removed; This item includes all sloped concrete, truncated domes and curb as shown in the shaded area of the standard drawings. The wall on the back side of the ramp shall remain. |
EA | 2 | |
202E981000B | REMOVAL MISC: (Show Less) Light Pole |
EA | 6 | |
202E981000C | REMOVAL MISC: (Show Less) Small Private Sign and Foundation, signs located in front of Wendy's. see Proposal Note Special: “Signs for Wendy’s” |
EA | 3 | |
202E981000D | REMOVAL MISC: (Show Less) Large Private Sign - Foundation Only. Foundation #1 - This foundation is for Bob Evans highway sign located behind the building. Foundation #2 - This foundation is for Wendy’s highway sign located behind the building. |
EA | 2 | |
202E981000E | REMOVAL MISC: (Show Less) Large Private Sign - Pole and Sign. This pole and sign is the highway pole and sign for Wendy’s which is located behind the building. see Proposal Note Special: “Signs for Wendy’s” |
EA | 1 | |
202E982000A | REMOVAL MISC: (Show Less) Handrail |
FT | 25 | |
202E982000B | REMOVAL MISC: (Show Less) Masonry Block Retaining Wall |
FT | 217 | |
203E10000 | EXCAVATION | CY | 6,763 | |
203E20000 | EMBANKMENT | CY | 211 | |
503E11100 | COFFERDAMS AND EXCAVATION BRACING | LS | 1 | |
503E21300 | UNCLASSIFIED EXCAVATION | LS | 1 | |
607E10000 | FENCE:MISC (Show Less) Decorative, As Per Plan, Commercial Delgrade Stratford Design or equivalent |
FT | 1,000 | |
608E10000 | 4" CONCRETE WALK | SF | 4,340 | |
608E520000A | CURB RAMP (Show Less) B3 |
SF | 400 | |
608E520000B | CURB RAMP (Show Less) B2 |
SF | 60 | |
610E50010 | RETAINING WALL, MISC.: (Show Less) Gravity, As Per Plan |
SF | 5,586 | |
625E35010 | REMOVE AND REERECT EXISTING LIGHT POLE | EACH | 7 | |
690E50100 | SPECIAL - MAILBOX SUPPORT SYSTEM, SINGLE | EACH | 2 | |
TRAFFIC CONTROL | ||||
621E00100 | RPM | EACH | 300 | |
621E54000 | RAISED PAVEMENT MARKER REMOVED | EACH | 75 | |
630E03100 | GROUND MOUNTED SUPPORT, NO. 3 POST | FT | 480 | |
630E80100 | SIGN, FLAT SHEET | SF | 261 | |
630E84900 | REMOVAL OF GROUND MOUNTED SIGN AND DISPOSAL | EACH | 11 | |
630E85100 | REMOVAL OF GROUND MOUNTED SIGN AND REERECTION | EACH | 2 | |
630E86002 | REMOVAL OF GROUND MOUNTED POST SUPPORT AND DISPOSAL | EACH | 11 | |
630E86010 | REMOVAL OF GROUND MOUNTED POST SUPPORT AND REERECTION | EACH | 4 | |
644E00100A | EDGE LINE, 4" | MILE | 0.07 | |
644E00100B | EDGE LINE, 4" | MILE | 0.53 | |
644E00200 | LANE LINE, 4 | MILE | 1.07 | |
644E00300 | CENTER LINE | MILE | 0.36 | |
644E00400 | CHANNELIZING LINE, 8 | FT | 3,430 | |
644E00500 | STOP LINE | FT | 350 | |
644E00600 | CROSSWALK LINE | FT | 940 | |
644E00700 | TRANSVERSE/DIAGONAL LINE | FT | 180 | |
644E00900 | ISLAND MARKING | SF | 809 | |
644E01200 | PARKING LOT STALL MARKING | FT | 212 | |
644E01300 | LANE ARROW | EACH | 55 | |
644E01500A | DOTTED LINE, 4" (Show Less) White |
FT | 600 | |
644E01500B | DOTTED LINE, 4" (Show Less) Yellow |
FT | 262 | |
644E01514 | DOTTED LINE, 8 | FT | 779 | |
SPECIAL01 | EXISTING GUIDE SIGN REMOVED AND RESET, AS PER PLAN | EA | 1 | |
TRAFFIC SIGNALS | ||||
630E11208 | OVERHEAD SIGN SUPPORT, TYPE TC-16.21, DESIGN 13, AS PER PLAN | EACH | 1 | |
630E79101 | SIGN HANGER ASSEMBLY, MAST ARM, AS PER PLAN | EACH | 7 | |
630E79500 | SIGN SUPPORT ASSEMBLY, POLE MOUNTED | EACH | 2 | |
630E80100 | SIGN, FLAT SHEET | SF | 51 | |
630E84510 | RIGID OVERHEAD SIGN SUPPORT FOUNDATION | EACH | 1 | |
630E87101 | REMOVAL OF OVERHEAD MOUNTED SIGN AND REERECTION, AS PER PLAN | EACH | 1 | |
631E90501 | INTERNALLY ILLUMINATED FIXED MESSAGE SIGN, AS PER PLAN | EACH | 2 | |
631E94406 | REMOVAL OF SIGNS WIRED (Show Less) these signs are identified as ES1 and ES2 on plan page 68/88 |
EACH | 2 | |
632E00301A | VEHICULAR SIGNAL HEAD, 3 SECTION, 12" LENS, 1-WAY, AS PER PLAN (Show Less) LED |
EA | 7 | |
632E00301B | VEHICULAR SIGNAL HEAD, 3 SECTION, 12" LENS, 1-WAY, AS PER PLAN (Show Less) LED |
EA | 5 | |
632E20731 | PEDESTRIAN SIGNAL HEAD (LED), TYPE D2, COUNTDOWN, AS PER PLAN | EACH | 6 | |
632E40500 | SIGNAL CABLE, 5 CONDUCTOR, NO. 14 AWG | FT | 435 | |
632E40700 | SIGNAL CABLE, 7 CONDUCTOR, NO. 14 AWG | FT | 320 | |
632E90020A | REMOVAL OF MISCELLANEOUS TRAFFIC SIGNAL ITEM (Show Less) Vehicular Signal Head |
EA | 6 | |
632E90020B | REMOVAL OF MISCELLANEOUS TRAFFIC SIGNAL ITEM (Show Less) Pedestrian Signal Head |
EA | 6 | |
632E90020C | REMOVAL OF MISCELLANEOUS TRAFFIC SIGNAL ITEM (Show Less) Pedestal |
EA | 1 | |
632E90400 | SIGNALIZATION, MISC.: (Show Less) Relocate Vehicular Signal Head |
EACH | 5 | |
632E90500 | SIGNALIZATION, MISC.: (Show Less) Unlash and Relash Messenger Wire |
FT | 775 | |
633E99000 | CONTROLLER ITEM, MISC.: (Show Less) Reprogram Controller |
EACH | 2 | |
809E69001 | ADVANCE RADAR DETECTION, AS PER PLAN | EACH | 2 | |
809E69101 | STOP-BAR RADAR DETECTION, AS PER PLAN | EACH | 2 | |
WATER WORKS | ||||
202E98100 | REMOVAL MISC.: (Show Less) Meter Chamber |
EACH | 1 | |
202E98600 | ABANDON MISC.: (Show Less) Water valve box abandon in place. Crush in top, fill with concrete |
EACH | 2 | |
623E10000 | CONSTRUCTION LAYOUT STAKES AND SURVEYING (Show Less) Water Main |
LS | 1 | |
638E01304 | 8" WATER MAIN DUCTILE IRON PIPE ANSI CLASS 53, MECHANICAL JOINTS AND FITTINGS | FT | 505 | |
638E04900 | 1" COPPER SERVICE BRANCH | FT | 34 | |
638E05000 | 1-1/2" COPPER SERVICE BRANCH | FT | 186 | |
638E06200 | POLYETHYLENE ENCASEMENT | FT | 505 | |
638E07900 | 8" GATE VALVE AND VALVE BOX | EACH | 4 | |
638E09400 | 8" X 8" TAPPING SLEEVE, VALVE AND VALVE BOX | EACH | 1 | |
638E09710 | 12" X 8" TAPPING SLEEVE, VALVE AND VALVE BOX | EACH | 1 | |
638E10200 | 6" FIRE HYDRANT (Show Less) Includes piping, tee, 6" gate valve completed |
EACH | 2 | |
638E10802 | WATER METER ADJUSTED TO GRADE | EA | 2 | |
638E10900 | SERVICE BOX ADJUSTED TO GRADE | EACH | 1 | |
638E11100 | METER AND CHAMBER REMOVED AND RESET | EACH | 1 | |
638E11200 | METER, SETTING, STOP AND CHAMBER | EACH | 1 | |
638E86404A | SPECIAL: EXPLORATORY EXCAVATION | HR | 4 | |
638E900000 | SPECIAL: ABANDON WATER SERVICE FOR SUNCO (Show Less) The contractor shall excavate in the eastbound traffic lane of Tylersville and turn off the corp stop at the tap on the water main to the abandoned service for the demolished Sunoco Gas Station. Roadway excavation will be backfilled with LSM. All work to be performed per Butler County Water & Sewer Specifications located at http://des.butlercountyohio.org/html/contractors/documents/2410.rev2012.pdf. |
LS | 1 | |
638E900001A | SPECIAL: PRIVATE WATERLINE TO BE RELCOATED (Show Less) Contingency Item to be used at the direction of the Engineer. Replacement of 300 LF of Private Water Line that may run down the Doc Drive Extension. |
FT | 300 | |
SPEC252E0100 | FULL DEPTH PAVEMENT REPAIR | SY | 30 | |
SPEC608E0101 | REMOVE AND REPLACE EXISTING CURB AND GUTTER | FT | 40 | |
SPEC608E0200 | REMOVE AND REPLACE CURB RAMP | EA | 3 | |
SPEC608E0300 | REMOVE AND REPLACE EXISTING WALK | SF | 200 | |
SPEC638002 | 8" SOLID SLEEVE | EA | 2 | |
SPEC638003 | 6" X 8" REDUCER | EA | 1 | |
SPEC638004 | CONNECT TO EXISTING 8" WATERMAIN | EA | 2 | |
SPEC638005 | CONNECT TO EXISTING 12" WATERMAIN | EA | 1 | |
SPEC832001 | 8" X 8" TEE | EA | 5 |