Project Items
Line | Item Number | Description (Hide All Extended Descriptions) | Units | Quantity |
---|---|---|---|---|
DRAINAGE | ||||
601E21050 | TIED CONCRETE BLOCK MAT, TYPE 1 | SY | 17.8 | |
601E21060 | TIED CONCRETE BLOCK MAT, TYPE 2 | SY | 20 | |
601E32200 | ROCK CHANNEL PROTECTION, TYPE C WITH FILTER | CY | 40 | |
602E20000 | CONCRETE MASONRY | CY | 11 | |
605E11100 | 6" SHALLOW PIPE UNDERDRAINS | FT | 27,133 | |
605E13300 | 6" UNCLASSIFIED PIPE UNDERDRAINS | FT | 2,540 | |
605E13500 | 6" ROCK CUT UNDERDRAINS | FT | 11,888 | |
605E14000 | 6" BASE PIPE UNDERDRAINS | FT | 19,005 | |
611E00510 | 6" CONDUIT, TYPE F FOR UNDERDRAIN OUTLETS | FT | 1,663 | |
611E01500 | 6" CONDUIT, TYPE F | FT | 150 | |
611E05900 | 15" CONDUIT, TYPE B | FT | 2,477 | |
611E06100 | 15" CONDUIT, TYPE C | FT | 654 | |
611E06700 | 15" CONDUIT, TYPE F (Show Less) 707.05 Type C or 707.21 |
FT | 802 | |
611E07400 | 18" CONDUIT, TYPE B | FT | 583 | |
611E07600 | 18" CONDUIT, TYPE C | FT | 50 | |
611E08900 | 21" CONDUIT, TYPE B | FT | 567 | |
611E10400 | 24" CONDUIT, TYPE B | FT | 1,070 | |
611E10600 | 24" CONDUIT, TYPE C | FT | 173 | |
611E10900 | 24" CONDUIT, TYPE D (Show Less) 706.02 |
FT | 33 | |
611E13400 | 30" CONDUIT, TYPE B | FT | 85 | |
611E13600 | 30" CONDUIT, TYPE C | FT | 176 | |
611E16400 | 36" CONDUIT, TYPE B | FT | 355 | |
611E16600 | 36" CONDUIT, TYPE C | FT | 12 | |
611E19600 | 42" CONDUIT, TYPE C | FT | 10 | |
611E21100 | 48" CONDUIT, TYPE C | FT | 26 | |
611E96600A | CONDUIT, BORED OR JACKED, 18" TYPE B | FT | 115 | |
611E96600B | CONDUIT, BORED OR JACKED, 24" TYPE D | FT | 97 | |
611E98150 | CATCH BASIN, NO. 3 | EACH | 2 | |
611E98180 | CATCH BASIN, NO. 3A | EACH | 21 | |
611E98330 | CATCH BASIN, NO. 5 WITHOUT APRON | EACH | 1 | |
611E98410 | CATCH BASIN, NO. 8 | EACH | 6 | |
611E98434 | CATCH BASIN, NO. 8A | EACH | 2 | |
611E98450 | CATCH BASIN, NO. 2-2A | EACH | 3 | |
611E98470 | CATCH BASIN, NO. 2-2B | EACH | 5 | |
611E98510 | CATCH BASIN, NO. 2-3 | EACH | 2 | |
611E99094 | INLET, NO. 3 FOR SINGLE SLOPE BARRIER, TYPE B | EACH | 9 | |
611E99104 | INLET, NO. 3 FOR SINGLE SLOPE BARRIER, TYPE C | EACH | 3 | |
611E99105 | INLET, NO. 3 FOR SINGLE SLOPE BARRIER, TYPE C, AS PER PLAN | EACH | 9 | |
611E99114 | INLET, NO. 3 FOR SINGLE SLOPE BARRIER, TYPE D | EACH | 15 | |
611E99574 | MANHOLE, NO. 3 | EACH | 8 | |
611E99660 | MANHOLE RECONSTRUCTED TO GRADE (Show Less) |
EACH | 5 | |
611E99710 | PRECAST REINFORCED CONCRETE OUTLET | EACH | 10 | |
EROSION CONTROL | ||||
601E32200 | ROCK CHANNEL PROTECTION, TYPE C WITH FILTER | CY | 2.6 | |
601E37500 | PAVED GUTTER, TYPE 1-2 | FT | 4,815 | |
659E00100 | SOIL ANALYSIS TEST | EACH | 1 | |
659E00300 | TOPSOIL | CY | 11,184 | |
659E10000 | SEEDING AND MULCHING | SY | 93,960 | |
659E14000 | REPAIR SEEDING AND MULCHING | SY | 4,698 | |
659E20000 | COMMERCIAL FERTILIZER | TON | 13 | |
659E31000 | LIME | ACRE | 20 | |
659E35000 | WATER | MGAL | 508 | |
659E40000 | MOWING | MSF | 23,490 | |
670E00500 | SLOPE EROSION PROTECTION | SY | 4,845 | |
670E00700 | DITCH EROSION PROTECTION | SY | 4,213 | |
832E15000 | STORM WATER POLLUTION PREVENTION PLAN (Show Less) This item includes all costs associated with the development, implementation, inspection and the required documentation of a Storm Water Pollution Prevention Plan for the Project described in this Contract. all of the specifications and requirements of ODOT supplemental specification 832 shall apply. |
LS | 1 | |
832E15002 | STORM WATER POLLUTION PREVENTION INSPECTIONS | LS | 1 | |
832E15010 | STORM WATER POLLUTION PREVENTION INSPECTION SOFTWARE SERVICES | LS | 1 | |
832E30000 | EROSION CONTROL (Show Less) This item is for the installation of Storm Water BMPS as defined in appendix "F" of ODOT supplemental specifications 832. The Contractor shall enter $1.00 in the unit price column and $180,000.00 in the total column. If the Contractor neglects to enter the correct figure(s) the Contractors bid will be corrected and the process for "Mistake In Bid" shall follow. No work will be recognized or paid under this item unless agreed upon and approved by an authorized representative of the Butler County Engineer's Office. |
EACH | 180,000 | |
836E10000 | SEEDING AND EROSION CONTROL WITH TURF REINFORCING MAT, TYPE 1 | SY | 798 | |
INCIDENTALS | ||||
614E11000 | MAINTAINING TRAFFIC | LS | 1 | |
619E16020 | FIELD OFFICE, TYPE C | MNTH | 14 | |
623E10000 | CONSTRUCTION LAYOUT STAKES AND SURVEYING | LS | 1 | |
624E10000 | MOBILIZATION | LS | 1 | |
802E00001 | PREMIUM ON INDUSTRIAL INSURANCE | LS | 1 | |
802E00002 | PREMIUM ON BID BOND | LS | 1 | |
802E00003 | CONTINGENCIES (Show Less) The Contractor shall enter $1.00 in the unit price column and $500,000.00 in the total column. If the Contractor neglects to enter the correct figure(s), the Contractor's bid will be corrected and the process for "Mistake in Bid" shall follow. This item will be used in the event that there are change orders in the Contract. No work will be paid or recognized under this item unless agreed upon in writing by an authorized representative of the Butler County Engineer's Office. |
EA | 500,000 | |
LIGHTING | ||||
202E98000 | REMOVAL MISC.: (Show Less) Remove and Disposal of abandon Duke Energy materials |
LS | 1 | |
625E00450 | CONNECTION, FUSED PULL APART | EACH | 19 | |
625E00460 | CONNECTION, UNFUSED PULL APART | EACH | 117 | |
625E00480 | CONNECTION, UNFUSED PERMANENT | EACH | 38 | |
625E15200 | LIGHT TOWER FOUNDATION, 36" X 25' DEEP | EACH | 1 | |
625E22990 | NO. 6 AWG 600 VOLT DISTRIBUTION CABLE | FT | 4,005 | |
625E23000 | NO. 4 AWG 600 VOLT DISTRIBUTION CABLE | FT | 4,791 | |
625E23100 | NO. 2 AWG 600 VOLT DISTRIBUTION CABLE | FT | 594 | |
625E23306 | NO. 10 AWG 600 VOLT DISTRIBUTION CABLE | FT | 6,924 | |
625E24000 | 1-1/2" DUCT CABLE WITH TWO NO. 4 AWG 600 VOLT CABLES | FT | 2,516 | |
625E25000 | CONDUIT, 3/4", 725.04 | FT | 742 | |
625E25408 | CONDUIT, 2", 725.051 | FT | 1,638 | |
625E25604 | CONDUIT, 4", 725.051 | FT | 4,369 | |
625E25900 | CONDUIT, JACKED OR DRILLED (Show Less) 725.04, 4 inch |
FT | 2,154 | |
625E29002 | TRENCH, 24" DEEP | FT | 6,102 | |
625E29931 | MEDIAN JUNCTION BOX, AS PER PLAN | EACH | 1 | |
625E30700 | PULL BOX, 725.08, 18 | EACH | 33 | |
625E31510 | PULL BOX REMOVED | EACH | 13 | |
625E31600A | PULL BOX, MISC: (Show Less) Transformer Box Pad, (with diamond plate cover), Installation Only |
EA | 10 | |
625E31600B | PULL BOX, MISC: (Show Less) Transformer Box Pad, Installation Only |
EA | 4 | |
625E31600C | PULL BOX, MISC: (Show Less) Modify Existing Pull Box |
EA | 1 | |
625E32000 | GROUND ROD | EACH | 4 | |
625E33001 | STRUCTURE GROUNDING SYSTEM, AS PER PLAN | EACH | 1 | |
625E35021 | RE-ERECT EXISTING LIGHT TOWER, AS PER PLAN | EACH | 1 | |
625E36000 | PLASTIC CAUTION TAPE | FT | 6,122 | |
625E40000 | SPECIAL - MAINTAIN EXISTING LIGHTING | LS | 1 | |
625E75351 | LIGHT TOWER REMOVED, AS PER PLAN | EACH | 1 | |
625E75500 | LIGHT POLE FOUNDATION REMOVED | EACH | 1 | |
625E98000A | LIGHTING MISC: POWER SERVICE, HIGH-MAST LIGHTING, 480V, 2-WIRE | EA | 2 | |
625E98000B | LIGHTING MISC: POWER SERVICE, SIGNAL LIGHTING, 120/240V, 3-WIRE, SINGLE-PHASE | EA | 2 | |
625E98000C | LIGHTING MISC: IN-WALL PEDESTRIAN LIGHT | EA | 35 | |
625E98000D | LIGHTING MISC: REMOVAL OF EXISTING LIGHT POLE, LUMINAIRE AND FOUNDATION | EA | 6 | |
MAINTENANCE OF TRAFFIC | ||||
254E01000 | PAVEMENT PLANING, ASPHALT CONCRETE (Show Less) 3 Inches |
SY | 20,610 | |
407E10000 | TACK COAT | GAL | 1,649 | |
442E10000 | ASPHALT CONCRETE SURFACE COURSE, 12.5 MM, TYPE A (446) | CY | 1,719 | |
607E98000 | FENCE, MISC.: (Show Less) Temporary Fence |
FT | 630 | |
614E11110 | LAW ENFORCEMENT OFFICER WITH PATROL CAR FOR ASSISTANCE | HOUR | 380 | |
614E11500 | WORKSITE TRAFFIC SUPERVISOR | MNTH | 14 | |
614E11630 | INCREASED BARRIER DELINEATION | FT | 5,501 | |
614E12350 | WORK ZONE IMPACT ATTENUATOR | EACH | 15 | |
614E12420 | DETOUR SIGNING | LS | 1 | |
614E12484 | WORK ZONE INCREASED PENALTIES SIGN | EACH | 4 | |
614E12500 | REPLACEMENT SIGN | EACH | 20 | |
614E12600 | REPLACEMENT DRUM | EACH | 100 | |
614E12801 | WORK ZONE RAISED PAVEMENT MARKER, AS PER PLAN | EACH | 2,013 | |
614E13000 | ASPHALT CONCRETE FOR MAINTAINING TRAFFIC | CY | 15 | |
614E13310 | BARRIER REFLECTOR, TYPE 1, ONE-WAY | EA | 761 | |
614E13350 | OBJECT MARKER, ONE WAY (Show Less) |
EACH | 873 | |
614E18030 | MAINTAINING TRAFFIC, MISC.: (Show Less) Rumble Strip Milled/Filled |
FT | 20,610 | |
614E18601 | PORTABLE CHANGEABLE MESSAGE SIGN, AS PER PLAN | SNMT | 16 | |
614E20110 | WORK ZONE LANE LINE, CLASS I, 6", 642 PAINT | MI | 11.7 | |
614E20560 | WORK ZONE LANE LINE, CLASS III, 6", 642 PAINT | MI | 1.63 | |
614E21550 | WORK ZONE CENTER LINE, CLASS III, 642 PAINT | MILE | 0.46 | |
614E22110 | WORK ZONE EDGE LINE, CLASS I, 6", 642 PAINT | MI | 17.55 | |
614E22360 | WORK ZONE EDGE LINE, CLASS III, 6", 642 PAINT | MI | 3.02 | |
614E23210 | WORK ZONE CHANNELIZING LINE, CLASS I, 12", 642 PAINT | FT | 32,115 | |
614E23690 | WORK ZONE CHANNELIZING LINE, CLASS III, 642 PAINT | FT | 9,928 | |
614E24200 | WORK ZONE DOTTED LINE, CLASS I, 642 PAINT | FT | 10,234 | |
614E24610 | WORK ZONE DOTTED LINE, CLASS III, 642 PAINT | FT | 5,667 | |
614E26200 | WORK ZONE STOP LINE, CLASS I, 642 PAINT | FT | 488 | |
614E26610 | WORK ZONE STOP LINE, CLASS III, 642 PAINT | FT | 690 | |
614E30200 | WORK ZONE ARROW, CLASS I, 642 PAINT | EACH | 163 | |
614E30650 | WORK ZONE ARROW, CLASS III, 642 PAINT | EACH | 149 | |
615E10000 | ROADS FOR MAINTAINING TRAFFIC | LS | 1 | |
615E20000 | PAVEMENT FOR MAINTAINING TRAFFIC, CLASS A | SY | 5,425 | |
616E10000 | WATER | MGAL | 330 | |
622E41000 | PORTABLE BARRIER, 32 | FT | 41,133 | |
622E41050 | PORTABLE BARRIER, "Y" CONNECTOR | EACH | 2 | |
808E18700 | DIGITAL SPEED LIMIT (DSL) SIGN ASSEMBLY | SNMT | 48 | |
PAVEMENT | ||||
254E01000 | PAVEMENT PLANING, ASPHALT CONCRETE | SY | 12,019 | |
302E46000 | ASPHALT CONCRETE BASE, PG64-22 | CY | 36,807 | |
304E20000 | AGGREGATE BASE | CY | 16,551 | |
407E10000 | TACK COAT | GAL | 19,728 | |
442E10000 | ASPHALT CONCRETE SURFACE COURSE, 12.5 MM, TYPE A (446) | CY | 4,270 | |
442E10100 | ASPHALT CONCRETE INTERMEDIATE COURSE, 19 MM, TYPE A (446) | CY | 6,380 | |
609E12000 | COMBINATION CURB AND GUTTER, TYPE 2 | FT | 3,084 | |
609E26000 | CURB, TYPE 6 | FT | 6,642 | |
609E70001 | 4" CONCRETE MEDIAN, AS PER PLAN | SY | 8,081 | |
RETAINING WALL (RW-01) | ||||
204E50000 | GEOTEXTILE FABRIC | SY | 68 | |
503E21300 | UNCLASSIFIED EXCAVATION | LS | 1 | |
507E00400 | STEEL PILES, MISC.: (Show Less) HP12x53 Soldier Piles |
FT | 183 | |
512E10100 | SEALING OF CONCRETE SURFACES (EPOXY-URETHANE) | SY | 82 | |
516E13600 | 1" PREFORMED EXPANSION JOINT FILLER | SF | 228 | |
518E62200 | STRUCTURE DRAINAGE, MISC.: (Show Less) 4" PVC Pipe Weephole |
EACH | 8 | |
524E94603 | DRILLED SHAFTS, 30" DIAMETER, ABOVE BEDROCK, AS PER PLAN | FT | 166 | |
610E50000A | RETAINING WALL MISC: PECAST CONCRETE PANEL LAGGING, 7'-10" X 8'-0" | EA | 14 | |
610E50000B | RETAINING WALL MISC: PRECAST CONCRETE PANEL LAGGING, 7'-10" X 4'-0" | EA | 8 | |
610E50010 | RETAINING WALL, MISC.: (Show Less) Temporary Hardwood Lagging |
SF | 65 | |
RETAINING WALL (RW-02) | ||||
203E20000 | EMBANKMENT | CY | 378 | |
503E11100 | COFFERDAMS AND EXCAVATION BRACING | LS | 1 | |
503E21301 | UNCLASSIFIED EXCAVATION, AS PER PLAN | LS | 1 | |
512E10100 | SEALING OF CONCRETE SURFACES (EPOXY-URETHANE) | SY | 470 | |
840E20000 | MECHANICALLY STABILIZED EARTH WALL (Show Less) AS PER PLAN |
SF | 4,868 | |
840E21000 | WALL EXCAVATION | CY | 2,170 | |
840E22001 | FOUNDATION PREPARATION, AS PER PLAN | SY | 494 | |
840E23000 | SELECT GRANULAR BACKFILL | CY | 2,498 | |
840E25010 | 6" DRAINAGE PIPE, PERFORATED | FT | 642 | |
840E25020 | 6" DRAINAGE PIPE, NON-PERFORATED | FT | 12 | |
840E26000 | CONCRETE COPING | FT | 315 | |
840E27000 | ON-SITE ASSISTANCE | DAY | 2 | |
ROADWAY | ||||
201E11000 | CLEARING AND GRUBBING | LS | 1 | |
202E20010 | HEADWALL REMOVED | EACH | 3 | |
202E23000 | PAVEMENT REMOVED | SY | 53,459 | |
202E30500 | CONCRETE MEDIAN REMOVED | FT | 20 | |
202E30700 | CONCRETE BARRIER REMOVED | FT | 663 | |
202E32000 | CURB REMOVED | FT | 1,509 | |
202E32500 | CURB AND GUTTER REMOVED | FT | 42 | |
202E35100 | PIPE REMOVED, 24" AND UNDER | FT | 882 | |
202E35200 | PIPE REMOVED, OVER 24 | FT | 358 | |
202E38000 | GUARDRAIL REMOVED | FT | 4,208 | |
202E58100 | CATCH BASIN REMOVED | EACH | 14 | |
202E75000 | FENCE REMOVED | FT | 1,229 | |
202E98100A | REMOVAL MISC: PRECAST CONCRETE OUTLET | EA | 6 | |
202E98100B | REMOVAL MISC: DECORATIVE WOODEN SIGN | EA | 5 | |
202E98200A | REMOVAL MISC: CONCRETE PAVED GUTTER | FT | 268 | |
202E98200B | REMOVAL MISC: BLOCK LANDSCAPE WALL | FT | 24 | |
202E98400A | REMOVAL MISC: CONCRETE PAD | SF | 14 | |
202E98400B | REMOVAL MISC: ROCK CHANNEL PROTECTION | SF | 4,564 | |
202E98700 | ABANDON MISC.: (Show Less) Pipe 24" and under |
FT | 569 | |
203E10000 | EXCAVATION | CY | 43,022 | |
203E20000 | EMBANKMENT | CY | 68,336 | |
204E10000 | SUBGRADE COMPACTION | SY | 9,431 | |
204E13001 | EXCAVATION OF SUBGRADE, AS PER PLAN | CY | 5,193 | |
204E20001 | EMBANKMENT, AS PER PLAN | CY | 5,193 | |
204E45000 | PROOF ROLLING | HOUR | 55 | |
206E10500 | CEMENT | TON | 2,572 | |
206E11000 | CURING COAT | SY | 99,240 | |
206E15010 | CEMENT STABILIZED SUBGRADE, 12 INCHES DEEP | SY | 99,240 | |
206E30000 | MIXTURE DESIGN FOR CHEMICALLY STABILIZED SOILS (Show Less) As Per Plan |
LS | 1 | |
512E10100 | SEALING OF CONCRETE SURFACES (EPOXY-URETHANE) | SY | 10,323 | |
530E13000 | SPECIAL - FORM LINER | SF | 3,612 | |
606E15050 | GUARDRAIL, TYPE MGS | FT | 5,875 | |
606E15100 | GUARDRAIL, TYPE MGS WITH LONG POSTS | FT | 1,375 | |
606E15150 | GUARDRAIL, TYPE MGS HALF POST SPACING | FT | 50 | |
606E15200 | GUARDRAIL, TYPE MGS HALF POST SPACING WITH LONG POSTS | FT | 25 | |
606E26150 | ANCHOR ASSEMBLY, MGS TYPE E | EACH | 18 | |
606E26550 | ANCHOR ASSEMBLY, MGS TYPE T | EACH | 14 | |
606E35002 | MGS BRIDGE TERMINAL ASSEMBLY, TYPE 1 (Show Less) |
EACH | 9 | |
606E35102 | MGS BRIDGE TERMINAL ASSEMBLY, TYPE 2 | EACH | 6 | |
607E23000 | FENCE, TYPE CLT | FT | 2,442 | |
608E10000 | 4" CONCRETE WALK | SF | 11,112 | |
608E52000 | CURB RAMP | SF | 1,019 | |
622E10060 | CONCRETE BARRIER, SINGLE SLOPE, TYPE B | FT | 2,090 | |
622E10120 | CONCRETE BARRIER, SINGLE SLOPE, TYPE C | FT | 3,557 | |
622E10121A | CONCRETE BARRIER, SINGLE SLOPE, TYPE C, AS PER PLAN (Plan A) | FT | 100 | |
622E10121B | CONCRETE BARRIER, SINGLE SLOPE, TYPE C, AS PER PLAN, (Plan B) | FT | 25 | |
622E10121C | CONCRETE BARRIER, SINGLE SLOPE, TYPE C, AS PER PLAN (Plan C) | FT | 67 | |
622E10121D | CONCRETE BARRIER, SINGLE SLOPE, TYPE C, AS PER PLAN (Plan D) | FT | 60 | |
622E10160 | CONCRETE BARRIER, SINGLE SLOPE, TYPE D | FT | 1,907 | |
622E10161 | CONCRETE BARRIER, SINGLE SLOPE, TYPE D, AS PER PLAN | FT | 1,142 | |
622E24001 | CONCRETE BARRIER, TYPE D, AS PER PLAN | FT | 174 | |
622E24840 | CONCRETE BARRIER END SECTION, TYPE B | EACH | 7 | |
622E25000 | CONCRETE BARRIER END SECTION, TYPE D | EACH | 4 | |
622E25004 | CONCRETE BARRIER, END ANCHORAGE, REINFORCED, TYPE B | EACH | 20 | |
622E25008 | CONCRETE BARRIER, END ANCHORAGE, REINFORCED, TYPE C | EACH | 30 | |
622E25050 | CONCRETE BARRIER, END ANCHORAGE, REINFORCED, TYPE D | EACH | 19 | |
878E25000 | INSPECTION AND COMPACTION TESTING OF UNBOUND MATERIALS | LS | 1 | |
SPECIAL03 | SPECIAL COMPACTION OF FOUNDATION SOILS FOR BRIDGE APPROACHES | LBS | 30,000 | |
STRUCTURE OVER 20' (BUT-75-0177) | ||||
202E11201 | PORTIONS OF STRUCTURE REMOVED, AS PER PLAN | LS | 1 | |
509E10001 | EPOXY COATED REINFORCING STEEL, AS PER PLAN | LB | 34,365 | |
510E10000 | DOWEL HOLES WITH NONSHRINK, NONMETALLIC GROUT | EACH | 4,416 | |
511E53014 | CLASS QC3 CONCRETE, MISC.: | CY | 262 | |
511E81300 | CONCRETE, MISC.: (Show Less) Mockup, Molded Concrete Surface |
EACH | 1 | |
512E10100 | SEALING OF CONCRETE SURFACES (EPOXY-URETHANE) | SY | 2,064 | |
516E13600 | 1" PREFORMED EXPANSION JOINT FILLER | SF | 34 | |
530E13000 | SPECIAL - FORM LINER | SF | 5,385 | |
607E98100A | FENCE, MISC: HSS4X4X1/4X5'-11 1/4" POST (Show Less) Including post cap plates |
EA | 86 | |
607E98100B | FENCE MISC: HSS3X3X1/4X7'-1 1/8" RAIL ASSEMBLY | EA | 136 | |
607E98100C | FENCE MISC: HSS3X3X104 EXPANSION RAIL ASSEMBLY | EA | 32 | |
607E98100D | FENCE MISC: HSS RAIL INNER EXPANSION SLEEVE (Show Less) With Incidentals |
EA | 32 | |
607E98100E | FENCE MISC: 1/2" DIAMETER X 0'-7" LING ASTM F593F BOLTS (Show Less) With Incidentals |
EA | 344 | |
607E98100F | FENCE MISC: 1/4" DIAMETER X 0'-1" LONG HEX WASHER HEAD SELF DRILLING STAINLESS STEEL SCREWS | EA | 2,016 | |
607E98100G | FENCE MISC: INNER POST SLEEVE AND BASE PLATE ASSEMBLY | EA | 86 | |
607E98100H | FENCE MISC: 1/2" DIAMETER X 1'-0" LONG ASTM F593G THREADED ANCHOR ROD (Show Less) With Incidentals |
EA | 688 | |
607E98200 | FENCE, MISC.: (Show Less) This item includes all labor, work and materials to pick up of the decorative vandal fence from West Chester facilities |
LUMP | 1 | |
847E10201 | SUPERPLASTICIZED DENSE CONCRETE OVERLAY, AS PER PLAN | SY | 9 | |
TRAFFIC CONTROL | ||||
618E40600 | RUMBLE STRIPS, (ASPHALT CONCRETE) | MILE | 7.6 | |
620E31200 | REMOVAL OF DELINEATOR | EACH | 37 | |
620E70000 | DELINEATOR, MISC.: (Show Less) Type D, Yellow |
EACH | 39 | |
621E00100 | RPM | EACH | 1,695 | |
621E54000 | RAISED PAVEMENT MARKER REMOVED | EACH | 1,655 | |
625E32000 | GROUND ROD | EACH | 19 | |
626E00102A | BARRIER REFLECTOR, TYPE 1 - ONE WAY | EA | 82 | |
626E00102B | BARRIER REFLECTOR, TYPE 1 - BI-DIRECTIONAL | EA | 79 | |
626E00110A | BARRIER REFLECTOR, TYPE 2 - ONE WAY | EA | 74 | |
626E00110B | BARRIER REFLECTOR, TYPE 2 - BI-DIRECTIONAL | EA | 87 | |
630E03100 | GROUND MOUNTED SUPPORT, NO. 3 POST | FT | 832.5 | |
630E06400 | GROUND MOUNTED STRUCTURAL BEAM SUPPORT, S4X7.7 | FT | 116 | |
630E06500 | GROUND MOUNTED STRUCTURAL BEAM SUPPORT, W6X9 | FT | 82 | |
630E07500 | GROUND MOUNTED STRUCTURAL BEAM SUPPORT, W10X22 | FT | 56 | |
630E07600 | GROUND MOUNTED STRUCTURAL BEAM SUPPORT, W10X12 | FT | 180 | |
630E08000 | GROUND MOUNTED STRUCTURAL BEAM SUPPORT, W12X30 | FT | 231.5 | |
630E08600 | SIGN POST REFLECTOR | EACH | 24 | |
630E09000 | BREAKAWAY STRUCTURAL BEAM CONNECTION | EACH | 28 | |
630E11103 | OVERHEAD SIGN SUPPORT, TYPE TC-16.21, DESIGN 11, AS PER PLAN (Show Less) Delivery / Installation Only (see Proposal note) |
EACH | 3 | |
630E11206 | OVERHEAD SIGN SUPPORT, TYPE TC-16.21, DESIGN 13 (Show Less) Delivery / Installation Only (see Proposal Note) |
EACH | 1 | |
630E11208 | OVERHEAD SIGN SUPPORT, TYPE TC-16.21, DESIGN 13, AS PER PLAN (Show Less) Delivery / Installation Only (see Proposal note) |
EACH | 2 | |
630E11212 | OVERHEAD SIGN SUPPORT, TYPE TC-16.21, DESIGN 14, AS PER PLAN (Show Less) Delivery / Installation Only (see proposal note) |
EACH | 1 | |
630E20401 | OVERHEAD SIGN SUPPORT, TYPE TC-12.30, DESIGN 4, AS PER PLAN (Show Less) Delivery / Installation Only (see Proposal note) |
EACH | 2 | |
630E20900 | OVERHEAD SIGN SUPPORT, TYPE TC-12.30, DESIGN 9 | EACH | 1 | |
630E21000 | OVERHEAD SIGN SUPPORT, TYPE TC-12.30, DESIGN 10 | EACH | 1 | |
630E21200 | OVERHEAD SIGN SUPPORT, TYPE TC-12.30, DESIGN 12 | EACH | 2 | |
630E66500 | OVERHEAD SIGN SUPPORT, TYPE TC-15.115 | EACH | 3 | |
630E74500 | OVERHEAD SIGN SUPPORT, MISC.: (Show Less) Mechanical Damper per TC-81.21 Mast Arm |
EACH | 3 | |
630E79100 | SIGN HANGER ASSEMBLY, MAST ARM | EACH | 22 | |
630E79611 | SIGN SUPPORT ASSEMBLY, BARRIER MOUNTED, AS PER PLAN | EACH | 6 | |
630E80100 | SIGN, FLAT SHEET | SF | 507 | |
630E80200 | SIGN, GROUND MOUNTED EXTRUSHEET | SF | 30 | |
630E80224 | SIGN, OVERHEAD EXTRUSHEET | SF | 1,750.5 | |
630E84500 | GROUND MOUNTED STRUCTURAL BEAM SUPPORT FOUNDATION | EACH | 28 | |
630E84510 | RIGID OVERHEAD SIGN SUPPORT FOUNDATION | EACH | 18 | |
630E84900 | REMOVAL OF GROUND MOUNTED SIGN AND DISPOSAL | EACH | 68 | |
630E85100 | REMOVAL OF GROUND MOUNTED SIGN AND REERECTION | EACH | 8 | |
630E85600 | REMOVAL OF GROUND MOUNTED MAJOR SIGN AND REERECTION | EACH | 10 | |
630E86002 | REMOVAL OF GROUND MOUNTED POST SUPPORT AND DISPOSAL | EACH | 67 | |
630E86102 | REMOVAL OF GROUND MOUNTED STRUCTURAL BEAM SUPPORT AND DISPOSAL | EACH | 32 | |
630E87100 | REMOVAL OF OVERHEAD MOUNTED SIGN AND REERECTION | EACH | 2 | |
630E87400 | REMOVAL OF OVERHEAD MOUNTED SIGN AND DISPOSAL | EACH | 18 | |
630E87500 | REMOVAL OF POLE MOUNTED SIGN AND DISPOSAL | EACH | 2 | |
630E89702 | REMOVAL OF OVERHEAD SIGN SUPPORT AND DISPOSAL | EACH | 11 | |
631E90501 | INTERNALLY ILLUMINATED FIXED MESSAGE SIGN, AS PER PLAN | EACH | 13 | |
631E94250 | REMOVAL OF LUMINAIRE | EACH | 16 | |
631E94350 | REMOVAL OF DISCONNECT SWITCH | EACH | 7 | |
631E94450 | REMOVAL OF BALLAST | EACH | 16 | |
631E94470 | REMOVAL OF SIGN SERVICE | EACH | 7 | |
644E00104 | EDGE LINE, 6 | MILE | 13.2 | |
644E00204 | LANE LINE, 6 | MILE | 15.23 | |
644E00300 | CENTER LINE | MILE | 0.05 | |
644E00404 | CHANNELIZING LINE, 12 | FT | 20,594 | |
644E00500 | STOP LINE | FT | 449 | |
644E00601 | CROSSWALK LINE, AS PER PLAN | FT | 206 | |
644E00720 | CHEVRON MARKING | FT | 576 | |
644E01300 | LANE ARROW | EACH | 178 | |
644E01360 | WRONG WAY ARROW | EACH | 4 | |
644E01510 | DOTTED LINE, 6 | FT | 4,375 | |
644E01520 | DOTTED LINE, 12 | FT | 4,029 | |
646E10010 | EDGE LINE, 6 | MILE | 0.3 | |
646E10110 | LANE LINE, 6 | MILE | 0.15 | |
646E10310 | CHANNELIZING LINE, 12 | FT | 772 | |
646E20300 | LANE ARROW | EACH | 15 | |
814E00010 | INTERSTATE ELONGATED ROUTE SHIELD SYMBOL MARKING, TYPE B125 | EACH | 4 | |
814E00016 | CARDINAL DIRECTION (NORTH, SOUTH, WEST & EAST) MARKING, TYPE B125 | EACH | 4 | |
TRAFFIC SIGNALS | ||||
625E18401 | BRACKET ARM, 20', AS PER PLAN (Show Less) Deliver / Installation Only (see Proposal note) |
EACH | 8 | |
625E25410 | CONDUIT, 2", 725.052 | FT | 476 | |
625E25908A | CONDUIT, JACKED OR DRILLED, 725.052 (3 inch) | FT | 364 | |
625E25908B | CONDUIT, JACKED OR DRILLED, 725.052 (4 inch) | FT | 1,770 | |
625E26253 | LUMINAIRE, CONVENTIONAL, SOLID STATE (LED), AS PER PLAN (Show Less) Type III |
EACH | 8 | |
625E29010 | TRENCH, 30" DEEP | FT | 476 | |
625E29011 | TRENCH, 30" DEEP, AS PER PLAN (Show Less) Contingency Item |
FT | 200 | |
625E30700 | PULL BOX, 725.08, 18 | EACH | 9 | |
625E30706 | PULL BOX, 725.08, 24 | EACH | 16 | |
625E30720 | PULL BOX, 725.08, 36 | EACH | 3 | |
630E79100 | SIGN HANGER ASSEMBLY, MAST ARM | EACH | 9 | |
631E90501 | INTERNALLY ILLUMINATED FIXED MESSAGE SIGN, AS PER PLAN | EACH | 9 | |
632E05007 | VEHICULAR SIGNAL HEAD, (LED), 3-SECTION, 12" LENS, 1-WAY, POLYCARBONATE, AS PER PLAN | EACH | 27 | |
632E20730 | PEDESTRIAN SIGNAL HEAD (LED), TYPE D2, COUNTDOWN | EACH | 8 | |
632E25000 | COVERING OF VEHICULAR SIGNAL HEAD | EACH | 27 | |
632E25010 | COVERING OF PEDESTRIAN SIGNAL HEAD | EACH | 8 | |
632E26000 | PEDESTRIAN PUSHBUTTON | EACH | 8 | |
632E40700 | SIGNAL CABLE, 7 CONDUCTOR, NO. 14 AWG | FT | 8,919 | |
632E64010 | SIGNAL SUPPORT FOUNDATION | EACH | 8 | |
632E64020 | PEDESTAL FOUNDATION | EACH | 15 | |
632E69320 | POWER CABLE, 3 CONDUCTOR, NO. 2 AWG | FT | 1,000 | |
632E70001 | POWER SERVICE, AS PER PLAN | EACH | 2 | |
632E77230 | SIGNAL SUPPORT, MECHANICAL DAMPER FOR TC-81.21 MAST ARM (GREATER THAN 59' IN LENGTH) | EACH | 1 | |
632E81071 | COMBINATION SIGNAL SUPPORT, TYPE TC-81.21, DESIGN 11, AS PER PLAN (Show Less) Delivery / Installation Only (see Proposal note) |
EACH | 1 | |
632E81091 | COMBINATION SIGNAL SUPPORT, TYPE TC-81.21, DESIGN 13, AS PER PLAN (Show Less) Delivery / Installation Only (see Proposal note) |
EACH | 6 | |
632E81095 | COMBINATION SIGNAL SUPPORT, TYPE TC-81.21, DESIGN 14, AS PER PLAN (Show Less) Delivery / Installation Only (see Proposal note) |
EACH | 1 | |
632E89901 | PEDESTAL, 8', TRANSFORMER BASE, AS PER PLAN (Show Less) Delivery / Installation Only (see Proposal note) |
EACH | 7 | |
632E90001 | PEDESTAL, 11', TRANSFORMER BASE, AS PER PLAN (Show Less) Delivery / Installation Only (see Proposal note) |
EACH | 8 | |
632E90101 | REMOVAL OF TRAFFIC SIGNAL INSTALLATION, AS PER PLAN | EACH | 2 | |
633E01551 | CONTROLLER UNIT, TYPE TS2/A2, WITH CABINET, TYPE TS2, AS PER PLAN | EACH | 2 | |
633E67100 | CABINET FOUNDATION | EACH | 2 | |
633E67200 | CONTROLLER WORK PAD | EACH | 2 | |
633E67301 | PREEMPTION, AS PER PLAN | EACH | 2 | |
633E75001 | UNINTERRUPTIBLE POWER SUPPLY (UPS), 1000 WATT, AS PER PLAN | EACH | 2 | |
809E65990 | ITS DEVICE, MISC.: (Show Less) Relocate Existing CCTV Camera |
EACH | 1 | |
809E69000 | ADVANCE RADAR DETECTION | EACH | 2 | |
809E69100 | STOP-BAR RADAR DETECTION | EACH | 8 | |
815E30001 | SPREAD SPECTRUM RADIO, AS PER PLAN | EACH | 2 | |
TRAFFIC SURVEILLANCE | ||||
625E00470 | CONNECTION, UNFUSED BOLTED | EACH | 3 | |
625E25304 | CONDUIT, 1-1/2", 725.051 | FT | 3,530 | |
625E25408 | CONDUIT, 2", 725.051 | FT | 5,757 | |
625E25604 | CONDUIT, 4", 725.051 | FT | 30 | |
625E25750 | CONDUIT, 4", MULTICELL, 725.20 , EPC-40 | FT | 1,437 | |
625E25802A | CONDUIT, CONCRETE ENCASED, 2 INCH, 725.051 | FT | 1,224 | |
625E25802B | CONDUIT, CONCRETE ENCASED, 4 INCH, 725.051 | FT | 250 | |
625E25906 | CONDUIT, JACKED OR DRILLED, 725.051 (Show Less) 4 Inch |
FT | 102 | |
625E25920 | CONDUIT, MISC.: (Show Less) 4 Inch, Multicell, 725.20, EPC-80, Jacked or Drilled |
FT | 102 | |
625E29000 | TRENCH | FT | 5,598 | |
625E30700 | PULL BOX, 725.08, 18 | EACH | 28 | |
625E30710 | PULL BOX, 725.08, 32 | EACH | 11 | |
625E32000 | GROUND ROD | EACH | 23 | |
630E70020 | OVERHEAD SIGN SUPPORT, DMS TRUSS, 115' | EACH | 1 | |
630E70051 | CATWALK, DMS TRUSS, AS PER PLAN | EACH | 1 | |
630E70070 | CONCRETE BARRIER MEDIAN OVERHEAD SIGN SUPPORT FOUNDATION, DMS TRUSS | EACH | 1 | |
630E70080 | OVERHEAD SIGN SUPPORT FOUNDATION, DMS TRUSS | EACH | 1 | |
630E79100 | SIGN HANGER ASSEMBLY, MAST ARM | EACH | 2 | |
630E80100 | SIGN, FLAT SHEET | SF | 32 | |
632E04905 | VEHICULAR SIGNAL HEAD, (LED), 2-SECTION, 12" LENS, 1-WAY, POLYCARBONATE, AS PER PLAN | EA | 8 | |
632E26500 | DETECTOR LOOP | EACH | 16 | |
632E40500 | SIGNAL CABLE, 5 CONDUCTOR, NO. 14 AWG | FT | 4,456 | |
632E64010 | SIGNAL SUPPORT FOUNDATION | EACH | 2 | |
632E65300 | LOOP DETECTOR LEAD-IN CABLE, 2 CONDUCTOR, NO. 14 AWG | FT | 9,202 | |
632E66104 | POWER CABLE, 3 CONDUCTOR, NO. 10 AWG | FT | 315 | |
632E69300 | POWER CABLE, 3 CONDUCTOR, NO. 4 AWG | FT | 990 | |
632E69310 | POWER CABLE, 1 CONDUCTOR, NO. 2 AWG | FT | 2,431 | |
632E70001A | POWER SERVICE, AS PER PLAN | EA | 2 | |
632E70001B | POWER SERVICE, AS PER PLAN A | EA | 1 | |
632E80402 | SIGNAL SUPPORT, TYPE TC-81.21, DESIGN 4 (Show Less) installation only |
EACH | 1 | |
632E80502 | SIGNAL SUPPORT, TYPE TC-81.21, DESIGN 11 (Show Less) installation only |
EACH | 1 | |
632E90400 | SIGNALIZATION, MISC.: (Show Less) Ramp Meter Sign |
EACH | 2 | |
633E67101 | CABINET FOUNDATION, AS PER PLAN | EACH | 3 | |
633E67201 | CONTROLLER WORK PAD, AS PER PLAN | EACH | 3 | |
633E99000A | CONTROLLER ITEM, MISC: (Show Less) Ramp Meter Controller |
EA | 2 | |
633E99000B | CONTROLLER ITEM, MISC: (Show Less) Remove Existing ITS Cabinet |
EA | 1 | |
809E60000 | CCTV IP-CAMERA SYSTEM, DOME-TYPE | EACH | 1 | |
809E61000 | CCTV CONCRETE POLE WITH LOWERING UNIT, 70 FEET | EACH | 1 | |
809E64550 | ETHERNET CABLE, OUTDOOR-RATED | FT | 754 | |
809E65000 | ITS CABINET - GROUND MOUNTED | EACH | 1 | |
809E65030 | ITS CABINET - RAMP METER | EACH | 2 | |
809E65990A | ITS DEVICE, MISC: RELOCATE EXISTING CONTROLLER UNIT | EA | 1 | |
809E65990B | ITS DEVICE MISC: REMOVE EXISTING CCTV AND POLE | EA | 1 | |
809E65990C | ITS DEVICE MISC: RELOCTE EXISTING DMS SIGN | EA | 1 | |
809E68900 | SIDE-FIRED RADAR DETECTOR | EACH | 2 | |
WATER WORK | ||||
638E00391 | 4" WATER MAIN POLYVINYL CHLORIDE PIPE FITTINGS, AS PER PLAN | FT | 3,630 |