bidVAULT

Welcome, Guest!
Log in | Project Owner Login | Privacy Policy | Disclaimer | Official bid entry time: 11/21/2024 4:43 AM EST | rss feed icon | calendar icon
 

Project Items

Line Item Number Description Units Quantity
01-ROADWAY
1 201E11000 CLEARING AND GRUBBING LS 1
2 202E23010 PAVEMENT REMOVED, ASPHALT SY 90
3 202E38000 GUARDRAIL REMOVED FT 242
4 202E75000A FENCE REMOVED FT 203
5 203E10000 EXCAVATION CY 50
6 203E20000 EMBANKMENT CY 191
7 204E10000 SUBGRADE COMPACTION SY 245
8 606E15050 GUARDRAIL, TYPE MGS FT 138
9 606E35002 MGS BRIDGE TERMINAL ASSEMBLY, TYPE 1 EACH 4
10 607E15000 FENCE, TYPE 47 FT 293
11 607E15000 FENCE, TYPE 47
Contingency
FT 70
12 659E10001 SEEDING AND MULCHING, AS PER PLAN SQ YD 1,055
13 659E20000 COMMERCIAL FERTILIZER TON 0.14
14 659E35000 WATER MGAL 3
15 670E00530 SLOPE EROSION PROTECTION MAT, TYPE C SQ YD 191
58 802E60303 SUBGRADE REPAIR CY 110
59 653E10000 TOPSOIL FURNISHED AND PLACED CY 118
02-PAVEMENT
16 254E01000 PAVEMENT PLANING, ASPHALT CONCRETE SY 419
17 301E46000 ASPHALT CONCRETE BASE, PG64-22 CU YD 36
18 304E20000 AGGREGATE BASE CU YD 39
19 407E20000 NON-TRACKING TACK COAT GAL 70
20 441E50300 ASPHALT CONCRETE INTERMEDIATE COURSE, TYPE 2, (448)
PG 64-22
CY 30
21 441E50000 ASPHALT CONCRETE SURFACE COURSE, TYPE 1, (448), PG64-22 CY 31
03-TRAFFIC CONTROL
22 626E00110B BARRIER REFLECTOR, TYPE 2 - BI-DIRECTIONAL EA 10
23 630E84900 REMOVAL OF GROUND MOUNTED SIGN AND DISPOSAL EACH 4
24 630E86002 REMOVAL OF GROUND MOUNTED POST SUPPORT AND DISPOSAL EACH 4
25 646E10200 CENTER LINE MILE 0.042
04-STRUCTURE (20' AND OVER)
26 202E11203 PORTIONS OF STRUCTURE REMOVED, OVER 20 FOOT SPAN, AS PER PLAN LS 1
27 202E23500 WEARING COURSE REMOVED SY 86
28 503E11100 COFFERDAMS AND EXCAVATION BRACING LS 1
29 503E21301 UNCLASSIFIED EXCAVATION, AS PER PLAN LS 1
30 509E10000 EPOXY COATED REINFORCING STEEL LB 4,158
31 510E10001 DOWEL HOLES WITH NONSHRINK, NONMETALLIC GROUT, AS PER PLAN EACH 32
32 511E99001 CLASS QC3 CONCRETE, SUPERSTRUCTURE, AS PER PLAN CY 19
33 511E81200 CONCRETE, MISC.:
Concrete Deck Test Slab
LS 1
34 511E44110 CLASS QC1 CONCRETE, ABUTMENT NOT INCLUDING FOOTING CU YD 1
36 512E10400 TREATING OF CONCRETE BRIDGE DECK WITH SRS SY 93
37 512E33000 TYPE 2 WATERPROOFING SY 8
38 515E12020 PRESTRESSED CONCRETE COMPOSITE BOX BEAM BRIDGE MEMBERS, LEVEL 1, CB17-36
39' - 4"
EACH 7
39 516E25000 NYLON REINFORCED NEOPRENE SHEETING SF 137
40 516E13600 1" PREFORMED EXPANSION JOINT FILLER SF 21
41 516E41100 1/8" PREFORMED BEARING PAD EACH 14
42 516E43100 ELASTOMERIC BEARING WITH INTERNAL LAMINATES ONLY (NEOPRENE) EACH 28
43 517E70000 RAILING (TWIN STEEL TUBE) FT 89.4
44 518E22300 SPECIAL - STEEL DRIP STRIP FT 88
45 519E11101 PATCHING CONCRETE STRUCTURE, AS PER PLAN
Contingency
SF 12
46 601E34100 ROCK CHANNEL PROTECTION, TYPE B WITHOUT FILTER CY 33
47 846E00110 POLYMER MODIFIED ASPHALT EXPANSION JOINT SYSTEM CF 12
60 512E10100 SEALING OF CONCRETE SURFACES (EPOXY-URETHANE) SQ YD 130
512E10050 SEALING OF CONCRETE SURFACES (NON-EPOXY) SQ YD 0
05-INCIDENTALS
48 614E11000 MAINTAINING TRAFFIC LS 1
49 623E10000 CONSTRUCTION LAYOUT STAKES AND SURVEYING LS 1
50 624E10000 MOBILIZATION LS 1
51 832E30000 EROSION CONTROL
THIS ITEM IS FOR THE INSTALLATION OF STORM WATER BMPS AS DEFINED IN APPENDIX "F" OF ODOT SUPPLEMENTAL SPECIFICATION 832. THE CONTRACTOR SHALL ENTER $1.00 IN THE UNIT PRICE COLUMN AND $10,000.00 IN THE TOTAL COLUMN. IF THE CONTRACTOR NEGLECTS TO ENTER THE CORRECT FIGURE(S) THE CONTRACTORS BID WILL BE CORRECTED AND THE PROCESS FOR "MISTAKE IN BID" SHALL FOLLOW. NO WORK WILL BE RECOGNIZED OR PAID UNDER THIS ITEM UNLESS AGREED UPON AND APPROVED BY AN AUTHORIZED REPRESENTATIVE OF THE BUTLER COUNTY ENGINEER'S OFFICE.
EACH 10,000
52 832E15000 STORM WATER POLLUTION PREVENTION PLAN
THIS ITEM INCLUDES ALL COSTS ASSOCIATED WITH THE DEVELOPEMENT, IMPLEMENTATION, INSPECTION AND THE REQUIRED DOCUMENTATION OF A STORM WATER POLLUTION PREVENTION PLAN FOR THE PROJECT DESCRIBED IN THIS CONTRACT. ALL OF THE SPECIFICATIONS AND REQUIREMENTS OF ODOT SUPPLEMENTAL SPECIFICIATION 832 SHALL APPLY.
LS 1
53 832E15002 STORM WATER POLLUTION PREVENTION INSPECTIONS LS 1
55 802E00001 PREMIUM ON INDUSTRIAL INSURANCE LS 1
56 802E00002 PREMIUM ON BID BOND LS 1
57 802E00003 CONTINGENCIES
THE CONTRACTOR SHALL ENTER $1.00 IN THE UNIT PRICE COLUMN AND $45,000.00 IN THE TOTAL COLUMN. IF THE CONTRACTOR NEGLECTS TO ENTER THE CORRECT FIGURE(S), THE CONTRACTOR'S BID SHALL BE CORRECTED AND THE PROCESS FOR MISTAKE IN BID SHALL FOLLOW. THIS ITEM WILL BE USED IN THE EVENT THAT THERE ARE CHANGE ORDERS DURING THE CONTRACT. NO EXTRA WORK OR CHANGE ORDER WILL BE PAID OR RECOGNIZED UNLESS AGREED UPON IN WRITING BY AN AUTHORIZED REPRESENTATIVE OF THE BUTLER COUNTY ENGINEER. ANY ITEM OVER THE PLAN QUANTITY WILL NOT BE PAID UNLESS IT HAS BEEN APPROVED BY AN AUTHORIZED REPRENTATIVE OF THE BUTLER COUNTY ENGINEER'S OFFICE
EA 45,000